Request a Free Energy Saver Kit from Energy Trust of Oregon: If you are a Pacific Power or Northwest Natural customer, Energy Trust of Oregon will send you a free Energy Saver Kit in about six weeks when you click here and register online. The kit includes energy-saving light bulbs and aerators to help you reduce energy costs right away.

Find Out More:

Click here to register for your free Home Energy Kit. 

About the Numbers:

How much energy could you save by registering for a free Energy Saver Kit from Energy Trust of Oregon? 

    In one year if you install 5 CFLs: 744 lbs CO2.
    In one year if you install 2 low-flow faucet aerators and one low-flow showerhead: 1,344 pounds CO2 for electric water heaters and 360 pounds CO2 for gas water heaters.

If everyone in Corvallis did this, in one year we would save 39,900 metric tons of CO2 (assuming half gas and half electric water heaters), which is equivalent to:

    Annual greenhouse gas emissions from 8,313 passenger vehicles.
    CO2 emissions from the electricity use of 5,490 homes for one year.
    Carbon sequestered by 1,023,077 tree seedlings grown for 10 years.
    Greenhouse gas emissions avoided by recycling 14,944 tons of waste instead of sending it to the landfill.

* According to EPA Greenhouse Gas Equivalencies Calculator.

Here is how we calculated that:


To estimate how much energy you could save by registering for a free Energy Saver Kit, let’s assume you install 5 CFLs and that these lamps are turned on for an average of 6 hours per day.  We’ll also assume you install two faucet aerators and one low-flow showerheads.

Replacing CFLs

    Calculating kilowatts:
1,000 watts is equal to 1 kilowatt, so a 60-watt incandescent bulb is equal to 0.060 kW (60 watts / 1,000 watts per kW = 0.060 kilowatts). A 15-watt CFL bulb is equal to .015 kW (15 watts / 1,000 watts per kW = 0.015 kilowatts).  The savings per bulb is 0.045 kW (0.060 kW - 0.015 kW = 0.045 kW savings per bulb).

    Calculating kilowatt-hours (kWh): Using 1 kilowatt for 1 hour is equal to 1 kWh, so 0.045 kW in energy savings for five bulbs, six hours per day, 30 days per month is equal to 40 kWh per month (0.045 kW savings per bulb x 5 bulbs x 6 hour per day x 30 days per month = 40.5 kWh per month).

    Calculating pounds (lbs) CO2: About 1.54 lbs of CO2 are emitted for every kWh used, so you could save 125 lbs CO2 per month (1.54 lbs CO2 x 40.5 kWh per month = 62.37 lbs CO2 saved per month, which we’ll round to 62 lbs).

Installing Low-Flow Aerators

There are a number of things we’ll need to consider to calculate the energy savings of installing low-flow aerators. First, we’ll need to calculate the potential water savings. Second, we’ll need to calculate how much energy it takes to produce the water in the municipal water-delivery system. Finally, we’ll need to calculate how much energy it takes to heat the water once it is in your home, and that depends on what type of water heater you have.

To help us with these calculations, let’s assume that the faucet aerator you install results in a savings of about 0.6 gallons per person per day and that 73% of water that comes out of the tap is heated.

    Calculating water savings: If two people live in your house, you would save 36 gallons per month (0.6 gallons per day per person x 30 days per month x 2 people per household = 36 gallons of water per month per household).  If 73% of this water is hot, you would save about 26 gallons of hot water and about 10 gallons of cold water (36 gallons of water x 73% hot water = 26.3 gallons hot water, which we’ll round to 26 gallons).

Calculating Energy to Treat and Deliver the Water

    Calculating kilowatt-hours (kWh): 
It takes 0.0033 kWh to produce 1 gallon of water, so using  low-flow faucet aerators would save 0.119 kWh per household per month (0.0033 kWh x 36 gallons = 0.119 kWh).

    Calculating pounds (lbs) of CO2: About 1.54 lbs of C02 are emitted for every kWh used, so you would save 0.183 lbs of CO2 per month (1.54 lbs of CO2 x 0.119 kWh = 0.183 lbs of CO2, which we’ll round to 0.18 lbs).

Calculating Energy to Heat the Water at Home

In this section, let’s assume that when the water comes into your house from the municipal system, it is about 55oF and that you have your water heater set at 120oF, which means you heat the water 65oF before it comes out of your tap (120oF - 55oF = 65oF)

Installing Low-Flow Aerators: Electric Water Heater

    Calculating kilowatt-hours (kWh) to heat one gallon of water:
It takes 1 BTU to raise 1 pound of water 1oF. One gallon of water weighs 8.34 lbs, and one BTU is equal to 0.0002931 kWh. So to heat one gallon of water 65oF you would use about 0.16 kWh/gal (0.0002931 kWh to raise 1.0 lb of water 1.0oF x 8.34 lbs in one gallon x 65oF = 0.16 kWh/gal).

    Calculating kWh to heat water: Above, we calculated that you would save about 26 gallons of hot water per month by installing a faucet aerator, so you would save 4.16 kWh a month (0.16 kWh per gallon x 26 gallons = 4.16 kWh per month).

    Calculating pounds (lbs) of CO2: About 1.54 lbs of CO2 are emitted for every kWh used, so you would save about 6.41 lbs of CO2 per month (1.54 lbs CO2 x 4.16 kWh = 6.41 lbs CO2 per month). In total, you would save 6.6 lbs CO2 per household per month (0.18 lbs to treat and deliver the water + 6.41 to heat the water = 6.59 total lbs CO2 saved, which we’ll round to 6.6 lbs).

Installing Low-Flow Aerators: Gas Water Heaters

    Calculating therms to heat one gallon of water:
It takes 1 BTU to raise 1 pound of water 1oF. A gallon of water weighs 8.34 lbs, and 1 BTU is equal to 0.0000099 therms.  So to heat one gallon of water 65oF you would use about 0.0054 therms/gal (0.0000099 therm to raise 1.0 lb of water 1.0oF x 8.34 lbs in one gallon x 65oF = 0.0054 therms/gal).

    Calculating therms saved: Above, we calculated that you would save about 26 gallons of hot water per month by installing faucet aerators, so you would save about 0.14 therms a month (0.0054 therms per gallon x 26 gallons = 0.14 therms per month).

    Calculating pounds (lbs) CO2: 
About 11.7 lbs of CO2 are emitted per therm used, so you would save 1.64 lbs of CO2 with low-flow faucets (11.7 lbs CO2 per therms x 0.14 therms = 1.64 lbs CO2 saved per month). In total, you would save about 1.8 lbs CO2 per month (0.18 lbs to treat and deliver the water + 1.64 to heat the water = 1.82 total lbs CO2 saved, which we’ll round to 1.8 lbs).

Installing a Low-Flow Showerhead

To help us with these calculations, let’s assume that your old showerhead used 2.5 gallons per minute (gpm) and your low-flow showerhead uses 1.5 gpm. Let’s also assume an average shower is 7 minutes and there are two people living in your household.

    Calculating water savings: If you replace a showerhead that uses 2.5 gallons per minute (gpm) with one that uses 1.5 gpm, you would save 7 gallons of hot water per 7-minute shower (2.5 gpm – 1.5 gpm = 1.0 gallons saved per minute x 7 minutes = 7 gallons saved). If each person on the household took one shower a day, you would save 420 gallons of hot water per month (7 gallons saved per shower x 2 people x 30 showers per month = 420 gallons of hot water saved per month per household).

Calculating Energy to Treat and Deliver the Water

    Calculating kilowatt-hours (kWh): 
It takes 0.0033 kWh to produce 1 gallon of water, so using a low-flow showerhead would save 1.4 kWh per household per month (0.0033 kWh x 420 gallons = 1.4 kWh).

    Calculating pounds (lbs) of CO2: About 1.54 lbs of CO2 are emitted for every kWh used, so you would save 2.15 lbs of CO2 per month (1.54 lbs of CO2 x 1.4 kWh = 2.15 lbs of CO2).

Calculating Energy to Heat the Water at Home

Installing a Low-Flow Showerhead: Electric Water Heater

    Calculating kilowatt-hours (kWh) to heat one gallon of water:
It takes 1 BTU to raise 1 pound of water 1oF. One gallon of water weighs 8.34 lbs, and one BTU is equal to 0.0002931 kWh. So to heat one gallon of water 65oF you would use about 0.16 kWh/gal (0.0002931 kWh to raise 1.0 lb of water 1.0oF x 8.34 lbs in one gallon x 65oF = 0.16 kWh/gal).

    Calculating kWh saved: Above, we calculated that you would save 420 gallons of water per month, so you could save 67.2 kWh per month per household (0.16 kWh per gallon x 420 gallons saved per shower = 67.2 kWh).

    Calculating pounds (lbs) of CO2:  About 1.54 lbs of CO2 are emitted for every kWh used, so you would save 103.5 lbs of CO2 per month (1.54 lbs CO2 x 67.2 kWh = 103.5 lbs CO2 per month). In total, you would save about 105 lbs CO2 per household per month (1.1 lbs CO2 to treat and deliver the water + 103.5 lbs CO2 to heat the water = 104.6 total lbs CO2 saved, which we’ll round to 105 lbs).

Installing a Low-Flow Showerhead: Energy Savings for Gas Water Heaters

    Calculating therms to heat one gallon of water:
It takes 1 BTU to raise 1 pound of water 1oF. A gallon of water weighs 8.34 lbs, and 1 BTU is equal to 0.0000099 therms.  So to heat one gallon of water 65oF you would use about 0.0054 therms/gal (0.0000099 therm to raise 1.0 lb of water 1.0oF x 8.34 lbs in one gallon x 65oF = 0.0054 therms/gal).

    Calculating therms saved:  You could save 2.27 therms in heating costs in one month of showering (0.0054 therms per gallon x 420 gallons saved per month = 2.27 therms per month).

    Calculating pounds (lbs) CO2:  About 11.7 lbs of CO2 are emitted per therm used, so you would save 26.54 lbs of CO2 per month with a low-flow showerhead (11.7 lbs CO2 per therm x 2.27 therms = 26.54 lbs CO2 saved).  In total, you would save about 28 lbs CO2  per household per month (1.1 lbs CO2 to treat and deliver the water + 26.54 lbs CO2 to heat the water = 27.64 total lbs CO2 saved, which we’ll round to 28 lbs).